| Output voltage | Regulation | Ripple & Noise | 1050W Output Power | 1250W Output Power |
| 3.3V | +-1% | 20mV | 20A | 20A |
| 5V | +-1% | 20mV | 20A | 20A |
| 12V | +-1% | 50mV | 87.5A | 104A |
| +5VSB | +-3% | 25mV | 3.0A | 3.0A |
| -12V | +-3% | 50mV | 0.3A | 0.3A |
| HOLD-UP TIME | 16msec (minimum) at 100% of full load at 230Vac input. |
| Surge Protection | Under all line voltage conditions of 90-264Vac, it is less than the rated value of its key components (including high-capacity rectifiers, fuses, and surge limiting devices). |
| standby power | <0.25W(WEEE, RoHS, ErP Lot 6 2014) |
| (OPP) | 1.3-1.5 Full load |
| (OVP) | +5V<7V、+12V<15.6V、+3.3V<4.3V |
| (SAFETY) | GB4943.1-2011、GB17625.1-2012、GB/T9254-2008 |
| EMC and Safety | CB/TUV/CTUVus/CE/FCC/CCC |
| altitude | 2000metre |
| pressurization | At 264Vac, the ground leakage current should be less than 1mA |